Gas Filter Proper operation of chlorine gas dosing equipment in chlorine gas systems can be ensured only if they are protected against impurities. With the chlorine gas filter, a product is available that removes impurities such as particles and chlorine condensates from the inflowing chlorine gas. Inside the chlorine gas filter, there is a Fiber filter element, on the surface of which the impurities are deposited when the gas flows through the filter.
Pressure Reducing Valve (PRV) is a spring-loaded diaphragm-actuated valve. The normal set pressure of a PRV is 1-2 kgs/cm2 for an upstream Pressure of 9-13 kgs/cm2 depending on the ambient temperature. The PRV provides superheat for the chlorine vapor thereby reducing the chance of reliquification in the pipeline downstream of PRV. If the PRV is by-passed the superheat provided by well be lost. Besides, chlorine gas metered at the flowmeter/rotameter will be more precise. If the flow of chlorine is metered at reduced pressure. Use PRV in conjunction with a gas filter to avoid impurities getting stuck in the seat of the PRV
We are providing completed services for water treatment plant especially in chlorination plant Spares Accessories like Automatic vacuum Regulator Automatic Vacuum Regulator is the most important part of the Chlorinator. Automatic Vacuum Regulator [AVR] is designed to close at pressure and open at a vacuum (normally). So, without vacuum, it should not allow chlorine gas to the injector of the Chlorinator. The logic is that, whenever there is loss of vacuum in the Injector due to no flow or low pressure of motive water, Pipe breakages in Vacuum line, the regulator does not allow the flow of hazardous Chlorine gas, making this system foolproof in terms of safety an operation
Function is to regulate the pressure drop created due to the differential across the Orifice of the Flow Control Valve. Differential Pressure Regulator [DPR] is provided to get stable reading across the Rotameter and also to regulate turbulent action of Vacuum to manageable level.
The accuracy of any chlorine metering system depends upon the consistency and repeatability of the density and velocity of gas at any given rate setting, which will in-turn, depend upon differential-pressure-regulator. The differential across the orifice (Flow-control Valve opening area) is automatically maintained within precise limits by Differential Pressure Regulator.
The other important function of this regulator is to reduce the highly turbulent action of the Injector vacuum to a steady manageable vacuum somewhat less than 625mm of Hg.
Further more, this Regulator maintains a constant vacuum on the down stream regardless of changes in water pressure in the Injector. If this function were not available, the metering rate through the Chlorinator would vary significantly with small changes in Injector operating pressure.
DPR comes with Chlorinators of capacities of 8 kgs/hr and above. In smaller capacities the pressure drop is negligible to provide DPR.
Releases the held-up volume of gas in the vacuum pipeline, during vacuum breakage. The set relief pressure is 0.3 KSC. These are Vacuum to close and pressure to relieve valve [>0.3 bar] 2. Vacuum Relief Valve: Relieves the excess vacuum (i.e.) vacuum greater than 500 mm of Hg. Prevents the effect of “Suck Back”. Also called Vacuum Breaker. 3. Check Valve: Allows only “Chlorine Gas” to pass through and prevents the water to enter 4. Drain valve: Drains the water that passed through a failed Check Valve. The second line of protection from water entering the system.Please change both the “O” rings of Check Valve and Drain Valve after you notice the water, gas passing through this valve.
Coiled Copper Tube Connector consists of an annealed copper tube (3/8” mm / O.D 10mm / 1.5mtrs. length) with Brass nipples and Brass unions (5/8” BSP [F]) on either side to suit chlorine container Valves. The brass nipple is brazed to the copper tube.
The Function of Coiled Copper Tube Connector allows flexibility of connection to the Tonner or Cylinder.
Chorine Valve · Meets IS 3224:2002, each production lot inspected and certified by Bureau of Indian Standard (BIS). · Approved by PESO Nagpur
For better regulation of fluid or water, we are manufacturing and supplying ball valve type screwed end/ socket END that is manufactured using high grade of raw materials. We offer these products in various models and sizes to satisfy our clients at the maximum level. Through proper fitting facilities, our products can be easily fitted to pipes. Applicability of these products is in pipelines, refineries and petrochemical industries
Operates independently by pull rod and push a lever
• Drench shower head made of highly visible yellow ABS
plastics
• GI pipe with powder coating for anti-corrosion ISI
marked
• Valve: Yellow ABS push plate
• Activation: For shower - Pull rod & For eyewash – Push
plate
• Water inlet and drain: 1-1/4 inches BSP
• Standard : IS: 10592:1982